Fast Turn-off Thyristor/Fast Recovery Diode Modules


Features
Typical Application Notes

1. Isolated mounting base, 2500V~
2. International standard package
3. Pressure contact technology with increased power cycling capability
4. Air-cooling for up to 200A. for over 300A,

air-cooling or water-cooling
5. Simple mounting and easy maintenance 
6. Space and weight saving

1. Inverter
2. Inductive heating
3. Chopper

IGT  VGT  VTM VFM IH are for 25¡ãC,

others are for Tj=Tjm, unless stated otherwise.


MKC  MHC
Type
VDRM
VRRM
IT(AV)@Tc
ITSM
I2t
dv/dt
di/dt
tq
trr
IDRM
IRRM
IGT
VGT
IH
VTM@ITM
VTO
rT
Rth(j-c)
Tjm
Outline
   
10ms
115°C
 
25°C
115°C
     
V
A
°C
kA
kA2s
V/μs
A/μs
μs
μs
mA
mA
V
mA
V
A
V
°C/W
°C
600-1600
75
85
1.60
13
800
200
15-35
1.5
30
150
2.5
100
2.20
225
0.85
4.88
0.200
115
600-1600
150
85
3.4
58
800
200
15-35
2.0
40
180
2.5
100
1.78
450
0.85
1.66
0.140
115
600-1600
200
85
4.8
115
800
200
15-35
3.0
50
180
2.5
100
1.77
600
0.90
1.15
0.100
115
600-1600
300
85
7.3
266
800
200
15-35
4.0
80
200
3.0
100
1.75
900
0.90
0.74
0.070
115
600-1600
300
55
5.6
160
800
200
15-35
3.0
50
200
3.0
100
2.20
900
0.90
1.17
0.110
115
600-1600
400
55
7.8
310
800
200
15-35
4.0
80
200
3.0
100
2.10
1200
0.90
0.80
0.087
115

MZC
Type
VRRM
IF(AV)@Tc
IFSM
I2t
IRRM
VFM@IFM
VFO
rF
Rth(j-c)
Tjm
Viso
Type
   
10ms
 
25°C
140°C
       
V
A
°C
kA
kA2s
mA
V
A
V
°C/W
°C
V(A.C)
600-1600
75
100
2.0
20
20
2.00
225
0.80
4.25
0.310
140
2500
600-1600
150
100
3.8
72
30
1.60
450
0.80
1.38
0.210
140
2500
600-1600
200
100
5.5
151
40
1.58
600
0.85
0.92
0.150
140
2500
600-1600
300
100
8.3
344
70
1.55
900
0.85
0.58
0.100
140
2500
600-1600
300
60
6.0
184
40
2.05
900
0.85
1.06
0.160
140
2500
600-1600
400
60
8.3
344
70
1.90
1200
0.85
0.68
0.130
140
2500
 
Remark: *water-cooling

Circuit

diagram